【Function
and Purpose】
Without
excavation, Shengli SL-206A cable failure locator is able to find out the
running direction, buried depth and failure points of underground
communications and electricity cables in a convenient and accurate way, so it is
the indispensable equipment and a quite helpful assistant for electricity,
communications and industrial enterprises.
【Characteristics】
1.
Small volume, less weight, and portable
2.
Easy detection and maintenance, having the function of automatic protection
3.
Low power supply voltage, available in AC/DC, strong adaptive capability
4.
Large power and high efficiency of the transmitter
5.
Small error in detection, strong anti-interference capability
6.
Stable and reliable performance, strong adaptive capability to environment
【Primary
Technical Parameters】
A.
Technical parameters of the transmitter:
1.Transmitting
power:≥25W,adjustable;
2.Transmitting
frequency: 1K±0.1Hz, clock frequency of 1-2Hz;
3.Output
impedance matching: 0-100Ω;
4.Transmitting
distance: ≤5Km(can be moved in steps beyond 5kms);
5.Working
current:≤3A,adjustable between 1 and 3A;
6.Working
power supply:12V(battery pack or car power);
7.Weight:2.8Kg
(battery excluded);
8.Overall
dimension:99×220×220
B.
Technical Parameters of the Detector
1.Sensitivity:0.1mV;
2.Running
positional deviation:<20cm;
3.Investigation
depth:≤5m;
4.
Working power supply: 6V cadmium-nickel battery pack
5.Weight:0.9Kg;
6.Overall
dimension: 60×160×120
【Detecting
Principles and Methodology】
By
sending a specified electrical signal to underground cables, the cable failure
locator determines the running direction and the depth of buried cables based
on the principle that the received signal is the smallest (almost zero) when
the probe is vertically tangent to the magnetic horizon.